3-29
Checking for nozzle clogging, and unclogging nozzles
Relationship between head row and test pattern
The relations between head row and test pattern print position are as follow.
If the printed pattern is abnormal (Cleaning)
STEPS:
1 Make sure that the printer is in LOCAL mode.
If it is in REMOTE mode, press the [REMOTE] key.
2 Press the [CLEANING] key.
3 Select the heads to be cleaned using the [] and [] or [] and [] keys, and press
the [ENTER] key.
Select a set of Head 1 and Head 2 or Head 3 and Head 4.
Head 1
Head 2
Head 3
Head 4
Media advance
direction
Pattern of head 1
Pattern of head 1
Pattern of head 2
Pattern of head 4
L. > [JV5-01]
width : ∗∗∗∗ mm
CLEANING
HEAD SELECT : 12. 34
CLEANING
HEAD SELECT : 12. 34