4-47
Cleaning of Flushing Box
STEPS:
1 Press the power switch on the front and make
sure that the power is off.
2 Turn off the main power switch on the rear side
of the unit.
3 Open the pump cover T.
4 Pull out the lid of the suction fan box.
Remove the grip fixing the suction fan box and then pull out the lid of the box.
Be sure to turn off the main power switch since there is the control board and
heater supply harness etc. in the pump cover T.
Pump cover T
Pull out the lid of the box