Cleaning of the UV lamp filter
To use this machine for a long time, clean the UV lamp filter at end of the day’s work.
1
Put out the UV lamp and switch OFF the power.
Press the power switch in the front of this machine.
2
Turn the main power switch OFF on the
side of this machine.
3
Open the front left cover.
4
Remove the UV lamp filter.
Remove the hand screw, and then remove the filter
and the filter holder by moving them upward.
Put on supplied goggles and gloves. Ink may splash into the eye.
When a screw is dropped in replacing of the filter, contact a distributor in your district or our
office.
If the message on the right is displayed, clean the UV
lamp filter as soon as possible.
Tools
Gloves Goggles Stainless tube brush
MA I NTENANCE WARN I NG
CLEAN UV LAMPF I LTER
Main power switch
Front left
cover