4-29
4
Maintenance
Setting nozzle face cleaning time
When set times of drawing are completed, nozzle face of the head is cleaned automatically to remove ink
droplets on the nozzle face.
1
Press the key in the local mode.
2
Select the [MAINTENANCE] by pressing the or
key, and press the key.
3
Select the [INT.WIPING] by pressing the or
key, and press the key.
4
Set the number of scanning times (OFF / 1 to 255) by
pressing the or key, and press the
key.
When [OFF] is set, periodical wiping is not executed.
5
Press the key to finish.
<LOCAL>
FUNCTION
FUNCT I ON
MA I NT ENANCE < ENT >
ENTER
MA I NT ENANCE
INT.WIPING <ent>
ENTER
INT.WIPING
SCAN COUNT = OFF
ENTER
END