– 4.11 –
4-2-7. Adjustment of the station position
[The case that needs adjustment]
If the amount of application of Wiper and Cap is not appropriate.
Usually, position adjustment of Station BKT (entire Station) is not performed.
Pertinent Wiper height
(measured and adjusted with the upper Head height)
Pertinent Cap height
(measured and adjusted with the upper Head height)
[Parts to be used]
Cap adjusting plate 0.5 (M503950)
•Wiper adjusting plate 0.5 (M504051)
0.5 mm
from 0.3 to 0.7 mm