- 2.22 -
Filling of the washing liquid at the end of the works
If you leave the head for discharge liquid with discharge liquid filled in for a long time, the life of
the head for discharge liquid will be shortened because the discharge liquid melts the water-shedding
part. To prevent the reduction of its life, at the end of daily operation drain the discharge liquid and
fill in the washing liquid.
STEPS:
1. At the LOCAL state, press the
[FUNCTION] key 4 times.
2. Press the [ENTER] key.
3. Use up/down key to select
[Washing].
4. Press the [ENTER] key.
5. Open the station cover.
6. Turn the all valves to [WASH].
7. Close the station cover.
8. Press the [ENTER] key.
9. Fill up the washing liquid after
initializing this machine.
10. It displays the remaining
run-time.
FUNCTION
DCG/WASH SW <ENT>
DCG/WASH SWITCH
Fill : Washing
Initialize
Please Wait
Filling
00:00:00
SW Valve To [WASH]
Press [ENT] key